S.L. 549.80 · Industrial Emissions (Titanium Dioxide) (S.L. 549.80)
S.L. 549.80 Art. 2013Regulations, 2002. L.N. 234 of 2002. 1. In case 550 kg of 2. In case (a) (b) (c) of 3. For ore, the the ores used. 1. The cubic meter of 101.3 kPa. 2. For 3 Nm as an 3. For calcination, (a) 6 (b) 4. For (a) 5 (b) 40 The monitoring of: (a) the chloride
Such installations shall apply to the competent authority for a permit by 7 July 2013 at the latest. SCHEDULE 1
EMISSION LIMIT VALUES FOR EMISSIONS INTO WATER of installations using the sulphate process (as an annual average): sulphate per tonne of titanium dioxide produced. of installations using the chloride process (as an annual average): 130 kg chloride per tonne of titanium dioxide produced using neutral rutile, 228 kg chloride per tonne of titanium dioxide produced using synthetic rutile, 330 kg chloride per tonne of titanium dioxide produced using slag. Installations discharging into salt water (estuarine, coastal, open sea) may be subject to an emission limit value of 450 kg chloride per tonne titanium dioxide produced using slag. installations using the chloride process and using more than one type of emission limit values in point 2 shall apply in proportion to the quantity of
SCHEDULE 2 EMISSION LIMIT VALUES INTO AIR emission limit values which are expressed as concentrations in mass per 3 (Nm ) shall be calculated at a temperature of 273.15 K, and a pressure
3 dust: 50 mg/Nm as an hourly average from major sources and 150 mg/
hourly average from any other source. gaseous sulphur dioxide and trioxide discharged from digestion and including acid droplets calculated as SO equivalent: 2 kg per tonne of titanium dioxide produced as an annual average; 3 500 mg/Nm as an hourly average for plants for the concentration of waste acid.
chlorine in the case of installations using the chloride process: 3 mg/Nm as a daily average; 3 mg/Nm at any time.
SCHEDULE 3 EMISSION MONITORING
monitoring of emissions into air shall include at least the continuous gaseous sulphur dioxide and trioxide discharged from digestion and calcination from plants for the concentration of waste acid in installations using the sulphate process;
(b) chlorine from major sources within installations using process;
(c) dust from major sources.
Änderungsgeschichte
- Amended by L.N. 234 of 2002