S.L. 427.26 · Aerosol Dispensers Regulations (S.L. 427.26)
S.L. 427.26 ст. 2requirements for the in order this of the foreseeable with construct and taking account 2.1.1. 2.1.2. 2.1.3. 2.2. must visibly (a) to (b) of (c) to (d) (e) 2.3. The capacity. 3. 3.1. The 3.1.1. 3.1.2. at 50°C 12 bar 13,2 bar 15 bar
GENERAL PROVISIONS 2.0 Without prejudice to specific provisions of the Annex on related to the flammability and pressure hazard, the person responsible marketing of aerosol dispensers is under an obligation to analyse the hazards to identify those which apply to his aerosol dispensers. Where appropriate, analysis shall include a consideration of the risks resulting from the inhalation spray ejected by the aerosol dispenser under normal and reasonably conditions of use, taking into account droplet size distribution in conjunction physical and chemical properties of the contents. He must then design, test it and, if applicable, draft special statements concerning its use, of his analysis.
2.1. Construction and equipment The filled aerosol dispenser must be such that, under normal conditions of use and storage, it complies with the provisions of this Schedule. The value must enable the aerosol to be virtually hermetically sealed under normal conditions of storage or transport and must be protected, for example by means of a protective cap, against any unintentional opening and any deterioration. There must be no possibility that the mechanical resistance of the aerosol dispenser can be impaired by the action of the substances contained in it, even during prolonged storage. Labelling
Without prejudice to Regulation (EC) No 1272/2008, each aerosol dispenser bear the following legible and indelible marking:
where the aerosol is classified as ‘non-flammable’ according to the criteria of point 1.9, the signal word ‘Warning’ and the other label elements for Aerosols Category 3 provided for in Table 2.3.1 of Annex I Regulation (EC) No 1272/2008; where the aerosol is classified as ‘flammable’ according to the criteria point 1.9, the signal word ‘Warning’ and the other label elements for Aerosols Category 2 provided for in Table 2.3.1 of Annex I to Regulation (EC) No 1272/2008; where the aerosol is classified as ‘extremely flammable’ according to the criteria of point 1.9, the signal word ‘Danger’ and the other label elements for Aerosols Category 1 provided for in Table 2.3.1 of Annex I Regulation (EC) No 1272/2008; where the aerosol dispenser is a consumer product, the precautionary statement P102 provided for in Part 1, Table 6.1 of Annex IV to Regulation (EC) No 1272/2008; any additional operating precautions which alert consumers to the specific dangers of the product; if the aerosol dispenser is accompanied by separate instructions for use, the latter must also reflect such operating precautions.
Volume of the liquid phase volume of the liquid phase at 50 °C must not exceed 90 % of the net
SPECIAL PROVISION FOR METAL AEROSOL DISPENSERS Capacity total capacity of these containers may not exceed 1 000 ml. Test pressure of containers
(a) For containers filled with a pressure of less than 6.7 bars at 50ºC, the test pressure must be equal to at least 10 bars.
(b) For containers filled at a pressure equal to or greater than 6.7 bars at 50ºC, the test pressure must be 50% higher than the internal pressure at 50ºC. Filling The pressure at 50°C in the aerosol dispenser must not exceed the values provided for in the following table, depending upon the content of gases in the aerosol dispenser:
Pressure Content of gases
Liquefied gas or mixture of gases having a flammable range with air at 20°C and a standard pressure of 1,013 bar Liquefied gas or mixture of gases not having a flammable range with air at 20°C and a standard pressure of 1,013 bar
Compressed gases or gases dissolved under pressure not having a flammable range with air at 20°C and a standard pressure of 1,013 bar